Is Brass Magnetic? How to Test Brass Fittings

BrassQuality CheckMaterial Testing

Brass does not stick to a magnet, so a pull on a fitting is a warning sign. Here is what the pull can mean, how to run the test, and what a magnet can never prove.

Short answer: No, solid brass is not magnetic. Brass is a copper-zinc alloy, and neither metal is ferromagnetic, so an ordinary hand magnet should not stick. If a magnet does stick to a brass fitting, the part is probably plated with nickel, contains iron, or has a steel core or insert. A magnet cannot tell you the brass grade or whether it is lead-free.

Key Takeaways

  • Brass does not attract a hand magnet. University of Illinois physicists answer the question flatly: brass is not magnetic.
  • A pull usually means a different metal is present: a nickel layer, iron inclusions, or a steel part inside or under the brass.
  • Nickel-plated brass fittings can show a slight pull because nickel is ferromagnetic.
  • A magnet test is a quick screen for brass-plated steel, not proof of grade, lead content or dezincification resistance.
  • For a purchase order, back the magnet test with a mill certificate and, where needed, an XRF analysis.

Is brass magnetic?

No, brass is not magnetic. It is an alloy of copper and zinc, and neither element is ferromagnetic.

The University of Illinois Physics Van puts it plainly: brass, a copper-zinc alloy, is not magnetic, and the common variants with other elements are not either. The response of pure brass to a hand magnet is too weak to notice.

The CDA record for cartridge brass C26000 agrees: it lists only copper and zinc as the main elements, with iron limited to 0.05% and lead to 0.07%. Nothing in that recipe is ferromagnetic.

  • What you will see: no attraction to a normal magnet.
  • What it means for fittings: a clean pass on the magnet test is the expected result.

Why does a magnet stick to some brass?

A magnet sticks when something other than brass is in the part. The usual causes are below.

  • Plating: nickel-plated or chrome-over-nickel fittings can show a slight pull, since nickel is ferromagnetic.
  • Iron contamination: small iron or nickel inclusions can give a very faint attraction to a strong magnet, as the Illinois physicists note.
  • Brass over steel: brass-coated or brass-colored steel is common in cheap hardware.
  • Steel components: springs, screws, stems or inserts inside an assembled valve.

The strength of the pull is a hint. A strong attraction suggests steel. A faint pull from a strong magnet suggests plating or trace iron.

Hot forged brass fittings in a tray with no magnetic pull on a hand magnet

How do you test a brass fitting with a magnet?

Hold a magnet to the bare body of the fitting and note whether it pulls, then repeat on a cleaned or scraped spot. The result is a screen, so record it with the lot number.

  1. Choose the magnet: a plain hand magnet first, then a strong neodymium magnet.
  2. Test the body: touch the magnet to several faces, away from steel inserts or springs.
  3. Check plating: if it pulls, scrape or file a small hidden spot and test again to see if the pull disappears.
  4. Compare with a known piece: a retained sample from an approved lot is the best reference.
  5. Record it: write down the lot, the magnet type and the result.

If the part is a valve, test the body separately from the stem and handle. A pull on an internal steel part is normal and says nothing about the body.

What can a magnet test not tell you?

A magnet cannot tell you the brass grade, the lead content or whether the part resists dezincification. Those properties depend on chemistry and heat treatment, which a magnet does not read.

QuestionMagnet testBetter method
Is it solid brass or plated steel?Useful screenScrape test, sectioning or XRF
Which brass grade is it?NoMill certificate, XRF
Is it lead-free?NoComposition test and the destination rule
Does it resist dezincification?NoISO 6509-1 test on finished parts
Is it brass or bronze?NoMill certificate, XRF

In the US, the US EPA defines “lead free” as a weighted average of 0.25% lead across wetted surfaces, which is a composition and certification question. Our guide to CW617N vs CW602N brass covers the grade side, and the article on DZR brass and ISO 6509 covers dezincification testing.

What should buyers check on incoming brass fittings?

Check composition on paper and on the part, because a magnet only catches the obvious fakes. A short incoming-inspection list works for most orders.

  • Mill certificate: chemical analysis per bar lot, matching the grade on the order.
  • Magnet screen: a quick pull test on a sample from each carton.
  • Appearance and thread: color, surface and thread gauge checks.
  • Plating: if plated, confirm the type, since it affects both the magnet result and the finish.
  • Third-party test: XRF or lab analysis when the order calls for it.

How does Fenilo check its brass?

Fenilo inspects all brass material before it enters production, as the first of five quality-control stages. Fittings are then hot forged, machined and assembled in one plant.

  • Incoming inspection: every brass material lot is inspected on arrival.
  • In-process checks: dimensions are inspected during machining.
  • Finished product: appearance, thread, assembly and packing are inspected before shipment.
  • Material: hot-forged CW617N / HPb59-1 brass; other grades can be discussed per project.
Finished inspection of brass fittings for appearance and thread at the Fenilo plant

Browse the brass fittings range and the brass pipe fittings, or read about our process on the about us page.

Need brass fittings with verified material?

Send us your drawing and the material you require, and we will discuss the grade and inspection points before quoting. Fittings are hot forged and CNC machined in our own plant in Yuhuan, Zhejiang, with five-stage quality control. Samples are available for assembly testing.

Discuss your brass requirements

FAQ

Is brass magnetic or non-magnetic?

Brass is non-magnetic; solid brass does not stick to a hand magnet. Brass is a copper-zinc alloy and neither metal is ferromagnetic. A pull on a brass-looking part points to plating, iron inclusions or steel underneath.

Is nickel-plated brass magnetic?

Nickel-plated brass can show a slight magnetic pull because nickel is ferromagnetic. The brass body itself is not magnetic. Scrape a small hidden spot and test again to see whether the pull comes from the plating.

Can a magnet tell real brass from brass-plated steel?

A magnet can usually tell real brass from brass-plated steel, because steel is strongly attracted and brass is not. A strong pull suggests a steel core. A faint pull may be plating or trace iron, so confirm with a scrape test or XRF.

Can brass become magnetic?

Brass does not become magnetic by itself, but a brass part can pick up a faint pull from small iron or nickel inclusions. The Illinois physicists note this is possible with a very strong magnet. It is a sign to check the alloy, not a property of clean brass.

Does a magnet test show if brass is lead-free?

A magnet test does not show whether brass is lead-free, because lead is not magnetic and the test reads only iron and nickel. Lead content comes from a composition test and the destination rule, such as the 0.25% US definition.

Bottom line: solid brass does not stick to a magnet, so a pull is a warning sign. Use the magnet as a quick screen, and rely on the mill certificate and composition testing for grade and lead.

Editorial note: The statement that brass is not magnetic and the note on iron or nickel inclusions are from the University of Illinois Physics Van page, read in November 2026; plating behavior is general metallurgy and was not tied to a separate standard. The US lead-free definition is from the EPA page. Fenilo’s inspection stages are from its published quality-control process; no test results are claimed here.